BNGGN - X0-8 TRU-TEST SUPREME X0-RUST ENAMEL
- MSDS: BNGGN
- Manufacturer: TRU TEST MANUFACTURING COMPANY
- Product Name: X0-8 TRU-TEST SUPREME X0-RUST ENAMEL
- National Stock Number: 8010-00F022821
Product Identification
Product ID:X0-8 TRU-TEST SUPREME X0-RUST ENAMEL
MSDS Date:07/25/1990
FSC:8010
NIIN:00F022821
MSDS Number: BNGGN
Responsible Party
CARY, IL 60013
US
Emergency Phone: 1-800-228-5635
Info Phone: (708) 639-5383
Cage: TRUTE
Contractor
Telephone: 708-639-5383
Cage: TRUTE
Ingredients
KEROSENE (PETROLEUM), HYDROTREATED; PETROLEUM DISTILLATE,
CAS: 64742-47-8
RTECS: OA5504000
Fraction By Weight: 30-45%
OSHA PEL 500 PPM
ACGIH TLV: 100 PPM
GROG; CALCIUM-BARIUM PHOSPHOSILICATE
CAS: 66402-68-4
Fraction By Weight: 1-5%
OSHA PEL 15 MG/CUM
ACGIH TLV: 10 MG/CUM
<380 GM/L
RTECS: 9999999VO
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION. SKIN: DRYING.
INHALATION: HEADACHE, DIZZINESS & NAUSEA.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: IRRITATION. SKIN: DRYING. INHALATION:
HEADACHE, DIZZINESS & NAUSEA.
First Aid
First Aid:EYES: WASH W/FRESH WATER. SKIN: WASH W/SOAP & WARM WATER.
INHALATION: REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION IF
REQUIRED. INGESTION: DON'T INDUCE VOMITING. KEEP PERSON WARM &
QUIET. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:105F
Lower Limits:0.9%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER FOG
Fire Fighting Procedures:TREAT AS A VOLATILE LIQUID FIRE. WATER SPRAY
MAY BE INEFFECTIVE. IF WATER SPRAY IS USED, FOG NOZZLES ARE
PREFERABLE.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT.
Accidental Release
Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. CONTAIN SPILL,
ABSORB LIQUID W/CLAY, SAND & FLOOR ABSORBENT.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. GROUND CONTAINERS WHEN POURING. AVOID FREE FALL OF >2-3
INCHES WHEN POURING.
Other Precautions:DON'T TAKE INTERNALLY. AVOID CONTACT W/SKIN.
Exposure Controls
Respiratory Protection:IF >TLV, USE A NIOSH/MSHA JOINTLY APPROVED AIR
SUPPLIED RESPIRATOR. USE AN APPROVED MECHANICAL FILTER TO REMOVE
SOLID AIRBORNE PARTICLES OF OVERSPRAY DURING APPLICATION.
Ventilation:SUFFICIENT MECHANICAL (GENERAL/LOCAL EXHAUST) TO KEEP
Eye Protection:SAFETY GLASSES
Other Protective Equipment:IMPERVIOUS CLOTHING & BOOTS.
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING, USING
BATHROOM.DON'T REUSE CONTAMINATED CLOTHING.
Supplemental Safety and Health
BOILING RANGE: 300-380F
Chemical Properties
Boiling Pt:B.P. Text:SEE SUPP
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME OR OTHER SOURCES
OF IGNITION.
Disposal
Waste Disposal Methods:CONTAMINATED ABSORBENT MAY BE DEPOSITED IN
LANDFILL IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS.
PREVENT RUN-OFF TO SEWERS, STREAMS OR OTHER BODIES OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.